Fbox
Library installation in PG5
This document has been
created to help you by installing Fbox libraries on PG5. Several method have
been used in the past for the installation and library package may have various
form. Misunderstanding have caused several erroneous installation which may be
difficult to correct.
To make the Fbox library
easier, Engiby has developed a suitable installation tool and all Engiby
libraries are now delivered as installation file which display clear
information (Product name, version, allowed PG5), propose options and guide the
user for the installation process.
In the intention to help
you by installing any library packages, other methods are also explained.
This file has now been
updated for the PG5 1.2 and 1.3 and old information from PG4 has been removed.
For password registration
on PG5 1.2 and 1.3 read also the description of the
registration procedure.
PG5 library organization
In PG5 (1.0, 1.1, 1.2, 1.3
and 1.4), the libraries are organized in 3 categories : the Standard, the
Application and the User libraries.
The standard libraries are automatically
installed with PG5 and are available on each PC.
The default folder is C:\Program Files\SAIA-Burgess\PG5\Libs\Std.
The application libraries
are usually installed afterwards by the user. These libraries may be unvailable
on other PCs. Take care by moving a project from a PC to another one.
Some exceptions:
- The LON library is also installed with PG5
- The Heavac and Modem libraries are also installed with PG5
The default folder is C:\Program Files\SAIA-Burgess\PG5\Libs\App.
The user library category
is foreseen for people developing there own libraries. The developer is
responsible itself for the library.
The default folder is C:\Program Files\SAIA-Burgess\PG5\Libs\Usr.
In PG5, the notion of
library does not only apply to Fbox. A library can also be an FBs library or
can be used by Add-On tools. Typically an Engiby library may be used in S-Fup
with Fboxes and by the NG-Configurator.
Despite, PG5 also has a FB folder where H-Module files are installed.
The default folder is C:\Program Files\SAIA-Burgess\PG5\Libs\FB.
In PG5, each one of these
folders can be changed at anytime in SPM in the menu Tools - Options -
Directories.
Libraries should not be
copied from one PG5 version to another one. For each library a PG5 update exist
(require for it) and will be installed in the correct folder. Some libraries
may work on a former PG5 version, but without warranty. Ask SAIA or Engiby in
case of doubt. In general, if the build is correctly executed, the runtime
function will be correct. But few exceptions exist!
For license reason, all
libraries must be updated for use in a new PG5 main version. E.g. from PG5 1.3
to PG5 1.4.
Library Override
Directories
This is a new feature of PG5
1.2. It allows you to work on a PG5 project made with a former PG5 version and
to continue to use the libraries of this old PG5. Engiby does not recommend
to work with override libraries unless you have received explicit
instructions. This can cause several incompatibility problems that will be hard
to solve. For instance: Add-On tools and configurators cannot always work with
older libraries.
The SAIA and Engiby
libraries are normally maintained and extended in a way to be upward
compatible. By using new libraries you will automatically have new features
available and known bugs are fixed.
Take care! In PG5 1.2, 1.3
and 1.4, when you open a project made with a former PG5 version, it will
propose you to set the override directories to continue to use the former
libraries. It is recommended to not accept this.
In case of problem, to
remove this setting, go to the Software settings, select the Directories tab and
uncheck the option 'Use Override Library Directories'. Check also 'Apply to all
CPU..'.
Check the Library
Versions in PG5 1.2, 1.3 and 1.4
PG5 1.2, 1.3 and 1.4 are
able to list the version of all editors as well as all installed libraries,
including the override libraries.
Go to the Help menu, and click Version Information.
Engiby Library Installer
To install function
libraries, Engiby include a suitable installation program with the library
itself. The library is delivered as self-extracting EXE-file. By executing the
EXE program, the user is guided for the installation of the library. For PG5
1.2, 1.3 and 1.4, the SAIA libraries also use the Engiby Library Installer.
The installation program
displays the concerned library, its version and allows you to check the
delivered files. Documentation files may also be installed and a link is created
in the Windows Start menu under Programs - Engiby Doc.
Before to install, select
the target PG5 version. Only the allowed and available PG5 packages are shown.
The destination folder is then displayed. Press the install button to start the
installation.
Before to start the
installation, check the displayed library name and version to ensure you are
installing the correct package. If a read-me is proposed you can read it before
(recommended) or after the installation.
Manual
installation of a library
This procedure can be used
if you have received a non-compressed files or files compressed in a format you
are able to decompressed. For instance ZIP files or if you need to copy library
files from a PC to another one. Remember that this procedure is not recommended
unless you have received explicit instructions from SAIA or Engiby.
First fined the correct
folder where the library must be installed. Read the above topics explaining
thePG5 library organization.
Find all files being part of the library. This may be difficult because some
files may have a different name than the usual library file names. The number
of files in a library may vary depending on its structure. Files may be shared
between several libraries. The list below, will help you to identify each
files.
|
Files
name |
Description |
|
GENERIC.LIN |
Library
information file |
|
GENERIC.DEF |
Fbox
definition |
|
GENERIC.DFF |
Family
list definition file |
|
GENERIC.IDX |
Text file
of the adjust windows |
|
GENERIC.LIB |
Library
of macros |
|
GENERIC.SXG |
Update
information |
|
GENERIC1.OBL |
Object
functions for PG4 V1.4x |
|
GENERIC2.OBL |
Object
functions for PG4 V2.0.xxx |
|
GENERIC3.OBL |
Object functions
for PG5 V1.0, 1.1 and up |
|
GENERIC4.OBL |
Object
functions for PG5 V1.1 and 1.2 |
|
GENERIC5.SRX |
Encrypted
source files for PG5 1.2 and up |
|
GENERIC.LIX |
Encrypted
macro library |
|
GENERIC.DAT |
Auxiliary
DAT file. Ex. Modem library. |
|
GENERIC.NGCC |
File for
the Engiby Configurator |
|
GENERIC.NG?? |
General
structure of auxiliary files for Engiby Add-On tools. |
|
GENE01.NGT |
File for
the NG-Trace software. |
|
GENERIC.HLP |
Fbox
and/or NG-Configurator Help file |
|
GENERIC.CNT |
Content of
Help file |
|
GENERICE.HLP |
Help
file, English |
|
GENERICD.HLP |
Help
file, German |
|
GENERICF.HLP |
Help
file, French |
|
GENERICE.CNT |
Content
of Help file, English |
|
GENERICD.CNT |
Content
of Help file, German |
|
GENERICF.CNT |
Content of
Help file, French |
In any cases, the files
with extensions .DEF, .IDX and .LIB are mandatory for all Fbox libraries.
The IDX, HLP and CNT files
may exist in different languages. The HLP and CNT files have usually different names,
while the IDX has the same name in all languages.
Trouble shouting and
typical errors
If you encountered a
problem by executing the EXE file, you can help yourself by the following:
Start Winzip manually, open the EXE-file and install the library files
manually. Please inform also Engiby about the problem.
You may also have a windows
error message because of missing DLL. This append sometimes on new installed
PCs. In this try to help yourself by installing the following package:
http://www.engiby.ch/download/vbrun60sp5.exe
It is an official Microsoft patch. You can also look for the newest service
pack and further information at Microsoft.
You should close S-Fup (and
any Add-On tool) to install a new library. After installation, the new
installed library must automatically appear in the Fbox selection tool.
If a library is not in the
list:
Take care also to not
install the same library in several folders of the same PG5 version (Std, App
and Usr). In this case, you will have error messages when S-Fup starts. Remove
manually all files of the concerned library and re-install it properly.
|
Back to Engiby main page Engiby / 26.12.2009 |